 - For areas where Type III distribution is required and
or Dark Sky security and facade lighting is required. Such as industrial build-
ings, universities, schools, apartment buildings, institutions, and government
establishments.
 - Die-cast aluminum housing with hinged full cutoff
front frame. The one-piece silicone gasket effectively limits outside
contaminants by sealing off the optical chamber. The reector is made of
die-formed 95% specular anodized aluminum for high efciency and type
II distribution. xtures have porcelain 4KV pulse rated medium
base socket with nickel-plated screw shell sockets.  xtures have 4 pin
plug in base & standard ballast of min. staring Temp. of 0
o
F/-18
o
C, extreme
Temp. ballast (XT) with -20
o
F/-30
o
C is available.
 - Dark bronze corrosion- resistant polyester powder nish is
standard
 - Frosted tempered at glass lens.
 - Type III standard. For other distribution please consult factory.
 - Convenient cast-in template for easy mounting over
standard 4” outlet box; or there are top, back, side 1/2” threaded hubs avail-
able for conduit entry.
- UL/ C-UL for wet location.
- Included except for CFL option.
All specications are subject to change without notice.
OWP-FC-401-MH-400-MVOLT
.1
.2
.5
1
2
5
10
20
5
4
3
2.75
2
1.75
1
0
1
2
3
0 1 2 2.25 3 3.75 4 5 6 7
House
Side
Street
Side
(Distance In Units Of Mounting Height)
(Values Based On 10 Foot Mounting Height)
(1/2 Maximum Candela Trace Shown As Dashed Curve)
(+) = Maximum Candela Point

EXTRA lARGE FUll CUT-OFF 
ORDERinG GUiDE

17"
18-1/4"
9"









WATTAGE vOlTAGE OPTiOnSSERiES

(400W High Pressure Sodium)
(320W Metal Halide)
(400W Metal Halide)
(2X26W Compact Fluorescent)
(2X32W Compact Fluorescent)
(2X42W Compact Fluorescent)
(40W Induction)
(80W Induction)








OWP-FC-401
- Photo control (120V only)
- Photo control (277V only)
- Single fuse
- Double fuse
- 750 lum. Emg. (CFL only)
- -20
o
F/-30
o
C Min. Temp. Bal. (CFL only)
ACCESSORiES
- Replacement lens kit
COlOR
 - BRONZE
 - WHITE
S H I P P I N G A V A I L A B L E
Extra Large Full Cut-Off Wall Pack


MVOLT(120/208/240/277)
120
347
480


MVOLT(120/277)
120
208
240
347

MVOLT(120/277)
Catalog Number